Main benefits

Suitable for Energy Measurement.
No delay / jitter between inputs / outputs
Ideal also for traction control & protection
Current loop transmission for noise immunity
Optional output offset for safety critical applications.
Compact and lightweight
Safe against internal arcs.
Extensively tested to safety & reliability
Expert customer support
Worldwide after-sales service

Product environment

Sécheron TMS is a versatile Traction Measurement System for rail vehicles. It provides signals that can be used for voltage detection, traction control and protection, and energy measurement functions. The TMS configurations cover the standalone Voltage Measurement Function (VMF) as well as the combined Voltage and Current Measurement Functions (VMF and CMF). They transmit safe, isolated, and accurate signals to a variety of on-board equipment.

The TMS is available on a stand-alone basis so that car builders and operators can install it on the vehicle roof. It can also be integrated into our smart, compact MODBOX® high-voltage enclosure with other high- and low-voltage functions for the electrical safety, measurement and control of the traction chain.

If you are looking for a more comprehensive solution, the TMS can also be delivered as part of the Sécheron Hasler Energy Metering System with energy meter including the Energy Calculation Function (ECF) and the Data Handling System (DHS).

All of our components and solutions are backed by Sécheron expert service during all phases of your project. Let us recommend the best solution to meet your needs. Whatever your choice, you can count on efficient support worldwide for the entire lifetime of your product.

Brochures

  • TMS Measurement Sensors
    EN
    Download
  • Supply program for rail transportation
    EN
    Download
  • High-voltage integrated systems MODBOX
    EN
    Download

Matrix_ACvoltage_current_voltage_sensors_01

Product description

  • Accuracy class 0.5R.

  • Overvoltage category OV4.

  • 3 isolated analog outputs, current loop type (voltage measurement).

  • Bipolar or Offset type outputs (voltage measurement).

  • AC applications 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz).

  • Maximum permanent measured voltage 31.5 kV.

  • Maximum peak measured voltage 50 kV.

  • Impulse withstand voltage 170 kV.

  • Bipolar output: DC offset = 0 mA; AC gain = 1.0 mA/kV.

  • Offset output : DC offset = 30 mA; AC gain = 0.4 mA/kV.

  • Measuring resistance: 10 to 200 Ohms (voltage measurement).

  • 1 or 2 current measuring transformers

  • Current measurement from 100 A to 630 A (15 kVAC), from 60 A to 400 A (25 kVAC).

  • Auxiliary supply voltage 24 to 110 VDC.

  • Vertical & horizontal installation.

  • Indoor or outdoor installation.

  • Compact & lightweight.

  • Suitable for ambient temperature - 40°C to +70°C.

  • Certified according to standards: EN 50463-2 / IEC 62888-2.

  • Certified according to TSI Loc&Pass.

  • Insulation material according to EN 45545-2.

 

 

Secheron Cta Careers

Request for quotation

For a request for quotation, please visit our dedicated contact center by clicking the Sécheron Support and then selecting "Request for Quotation" in the Help topics.